Polluted A/C Ducts
June 12, 2026A recent study looked at thousands of duct liner samples from buildings with air problems and found nearly half covered in dirt. This dirty stuff likely stuck around long enough to cause or keep indoor air issues going—serious enough to call for a full check-up. Most people think dust plus moisture makes mold appear, but a top U.S. lab found some liners let mold grow with moisture alone. That research also showed mold grew very differently on various brands of similar insulation and even between liners from the same brand, making it really tough for building managers to know when to replace them. If fresh indoor air and avoiding big repair bills matter, getting these facts will save plenty of trouble.
Bare Metal
In all justness, also unlined air ducts will sustain microbial development if water and also nutrients are present, leading some advocates – most significantly the North American Insulation Manufacturers Organization (NAIMA) – to assert that the task is to concentrate on maintaining air ducts completely dry as well as tidy, instead of implicating the lining material. NAIMA, as well as others, point out that the insulation supplies sufficient advantages to exceed the dangers. Nevertheless, this does not mollify others in the indoor air neighborhood.
Development of Various Linings
Another current study examined the capacity for fungal development on different types of liners under different moisture conditions. The scientists checked out how the linings performed in what would generally be thought about high moisture situations – in between 85% and 97% family member moisture (RH). They researched the materials in high humidity when moistened, soiled, and tidy.

The products they researched included:
- Fiberglass (FDL) An as well as FDL-C: > 44% -98% fibrous glass, 1% -18% urea polymer of phenol and also formaldehyde or urea-extended phenol-melamine-formaldehyde resin, <0.1% formaldehyde;
- FDL-B: 82% -98% coarse glass, 2% -18% ureaextended phenol-formaldehyde resin (healed) or urea-extended phenol-melamine-formaldehyde material (treated), <1% nonwoven, Foil-Skrim-Kraft or plastic strugglings with or vinyl or latex finishes;
- Fiberglass air duct board: 85% -96% fibrous glass wool, 4% -15% healed binder, <1% formaldehyde; as well as
- Fiberglass insulation: 90% -95% refractory ceramic fiber, 0% -10% phenol formaldehyde.
New products were purchased from commercial suppliers. The scientists likewise examined made use of products drawn from old structures. The used products were similar in look to the new products, but researchers couldn’t identify their origin. First, the researchers checked out all 5 examples after positioning them in an ecological chamber at 97% humidity as well as measuring microbial development. After that, they moistened the examples to see what result carried contamination. Ultimately, they dirtied the examples to see exactly how that influenced the growth.
During the time the brand-new product examples were at 97% RH alone, only FDL-A supported the development of the examination fungi – Penicillium – that had been put on the samples. FDL-B, which had actually been manufactured with a “permanent biocide,” really revealed a 1-log reduction. The testing duration lasted six weeks. When the materials were wetted with sterile water, FDL-A displayed fungal growth comparable to what was discovered during the high RH duration alone. FDL-B showed an even better decrease in growth. FDL-C, however, underwent a 2-log adjustment over the test period, while the various other materials once again showed no growth. When the materials were moderately soiled, all samples showed significant increases in fungal growth.
Effects of RH Alone
When the FDL-A was kept in a chamber at various RH degrees – 85%, 90%, 94%, as well as 97% – the examples exhibited a slight decrease in fungal development during the first week. From the 2nd week on, the samples kept at 97% raised progressively throughout the period. Nevertheless, the sample kept at 94%, while it at first followed the exact same pattern, and started showing growth during the sixth week. When the researchers repeated the experiment on FDL-A samples that had actually been greatly stained, making use of RH levels of 85%, 90%, as well as 94%, those at the two greater levels began revealing development after the first week. The sample held at 85% initially revealed decreased growth, however, began revealing growth by the 5th week. Utilized air duct products, from old buildings, were all able to sustain development immediately when kept at 97% RH. Maintain your AC unit with the help of an affordable ac service from this link.